I_Open 0.36T Magnetic Resonance Imaging System

Introduction

•  Homogeneity, Large Gap Space, small size and light weight.
•  The Eddy Current is reduced to the minimum through the use of Special High Resistance Materials.

 

Gradient System

•  The Advanced Design of the Inversion Method provides the Gradient System with Very High Linearity and Slew Rate, and
   insures the Highest Image Resolution.
•  I_Open's Unique design of the Active Shield Flat Gradient System decreases the Eddy Current to a very minimum and
   completely avoid the problem of Eddy Current that trouble most of the Permanent MRI Systems.
•  Image quality is improved greatly over similar Open Magnet Systems.

 

RF Transmitter System

•  Quadrature Design of Flat Transmitter Coil has contributed to improved uniformity and efficiency of the System and makes
   the System Unique as a fully open type MRI. The pulse transmitting power is up to 6KW.

 

RF Receiving System

•  The Special design of Quadrature Receiving Coil GreatlyImproves the signal to noise ratio.
•  Low noise build-in preamplifiers in the Coils reduce the signal attenuation, this in terms reduces the effect of noise greatly.
•  Auto Tuning simplifies the System's operation and keeps the System working in the best condition.

 

Friendly Interface & Easy operating

Powerful scanning software

I_Open provides Scan Control Software to help the customer easily set up Imaging Scans and Monitor the scans in a easy and friendly way: Easy and well designed menu are provided to set up scan parameters; Pilot scans allow you to precisely set slice positions; Easy menu also allows you to select Imaging Sequences: Auto adjustment of Resonance Frequency; Auto adjustment of Receiver and Transmitter Gain; Auto adjustment of Shimming; And Scan Process Monitoring in real time is also included.

 

Plenty of imaging processing functions

I_Open MRI system provides the most powerful Image Display and Process Software available on any Present Open MRI: Multi-Window Display; Display Window Adjustment; Image Zoom; Image Rotating; Distance Measurement; Angle Measurement; Region of Interesting Process; Image Enhancement; Image Smooth; Background Noise Eliminating; Image Text Note; Image Parameter Display; DICOM 3.0 Interface; MIP and MPR of 3D Images.


Software update: Free upgrading of Software are provided within Time Frame determined at Time of Purchase.

  

Prompt and Comprehensive Service

•  First Line Service will be provided by your Local Dealer .This Service will be supplement by a complete Distributor's Service
 Operation.
•  Further service support as required will be provided by Wandong , China .
•  Efficient and Professional Service will be provided 24 Hours Service Hot-Line will be available

 

High Performance/Price Ratio, Includes:

•  Low Running Cost
•  Compact Installation Space
•  Low Environmental Requirement

Capability

Configuration

Magnet

•  Field strength 0.36T±0.005T
•  Shimming Passive + Digital shimming
•  Dimension 1.8m (L) × 1.3m (W) × 1.8m (H)
•  Net weight 16T
•  Patient gap 410mm
•  Homogeneity 5ppm (Vrms)/40cmDSV

 

Gradient system

•  Gradient strength 15mT/m
•  Slew rate 55mT/m/ms
•  Gradient linearity <5%
•  Eddy current prevent Active shield
•  Cooling mode water

 

Receiving coils

•  Low noise build-in preamplifier
•  Noise figure <0.5dB
•  High isolation and low insertion loss build-in combiner
•  Quadrature coil

 

RF system

•  Pulse transmitting power 6kW
•  Center frequency 15.3MHz±0.25MHz
•  High isolation and low insertion loss power splitter

 

Sequence

•  Spin Echo (SE)
•  Gradient Echo (GE)
•  Ivertion Recovery (IR)
•  Fast Spin Echo (FSE)
•  Fast Gradient Echo (FGE)
•  Magnetic Resonance Angiography (MRA)
•  Short Ivertion Time Recovery (STIR)
•  Flow Attenuation Ivertion Recovery (FLAIR)
•  Magnetization Transfer Contrast (MTC)
•  Magnetic Resonance Choleopancreatography (MRCP)

 

Image

•  T1\T2, Mixture Weighted, Proton Density, MRA, Water/Fat Imaging
•  Max Fov 400mm ; Min Fov 20mm
•  Min 2Dslice thickness 1.5mm ; Min 3D slice thickness 0.5mm
•  Max Square Matrix 1024 × 1024

 

Spectrometer and Electronics

•  Sampling rate 400MHz in 16bits
•  16 bits Gradient Wave Form and Digital Pre-emphasis
•  16 bits Arbitrary Wave Form
•  Standard TCP/IP Ethernet Connection
•  CPU ≥ P4 2.8G
•  Memory ≥ 1G
•  Hard disk ≥ 160G
•  Display LCD Color Monitor 18" TFT
•  Archives CD-RW
•  Operating System WindowsTM XP

 

Space requirement

•  Scan Room 20m2
•  Control Room 10m2
•  Equipment Room 10m2

 

Option

•  Advanced MRA Software Package
•  Advanced 3D MRI Software Package
•  Independent Medical Imaging Processing Workstation
•  Image Processing, Database, DICOM hardcopy, Documents

Pictures

 

 

 

top

 

 
  BEIJING TEDA ORIENTAL MEDICAL EQUIPMENT CO.,LTD. 京IPC备06056927号